Active Tactile Sensibility of Branemark Protocol Prostheses: A Case-Control Clinical Study
Few studies have assessed active tactile sensibility in patients rehabilitated with implants. Improved knowledge about functional tactile sensibility will contribute to several clinical applications, such as protocols for immediate loading, prosthesis design, occlusal improvement in implantology, an...
Gespeichert in:
Veröffentlicht in: | Materials 2021-08, Vol.14 (16), p.4644, Article 4644 |
---|---|
Hauptverfasser: | , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Few studies have assessed active tactile sensibility in patients rehabilitated with implants. Improved knowledge about functional tactile sensibility will contribute to several clinical applications, such as protocols for immediate loading, prosthesis design, occlusal improvement in implantology, and physiological integration of implant-supported prostheses. The present study evaluated active tactile sensibility in patients rehabilitated with Branemark-type mandibular prostheses that impede the total mucosa-supported maxillary prosthesis. Thirty-five subjects participated in this study. The experimental group (n = 18) inclusion criteria were as follows: Branemark-type prosthesis and a total mucosa-supported maxillary prosthesis. The control group (n = 17) was composed of participants with complete healthy dentition. Carbon foils with different thicknesses (12 mu m, 24 mu m, 40 mu m, 80 mu m, and 200 mu m) were placed in the premolar region to evaluate the brink of active oral tactile sensibility. The researchers assessed the participants 120 times. After evaluation, we observed a statistical difference (p < 0.05) between the groups. Additionally, the degree of sensibility was found for all thicknesses, except for 12 mu m, on both sides. There was a more significant increase in perception in the control group as the carbon thickness increased. The tactile sensibility threshold was 2.5 times greater for participants with prostheses. Thus, the tactile sensibility for mandibular implant-supported and maxillary mucosa-supported prostheses is significantly lower than that of dentate patients, which was detected above the thickness of 80 mu m; in patients with natural dentition, different thicknesses were seen starting from 24 mu m. |
---|---|
ISSN: | 1996-1944 1996-1944 |
DOI: | 10.3390/ma14164644 |