Evaluation of extraction-free RT-qPCR methods for SARS-CoV-2 diagnostics
Extraction-based real-time reverse transcription quantitative polymerase chain reaction (RT-qPCR) is currently the “gold standard” in SARS-CoV-2 diagnostics. However, some extraction-free RT-qPCR techniques have recently been developed. In this study, we compared the sensitivity of traditional extra...
Gespeichert in:
Veröffentlicht in: | Archives of virology 2021-10, Vol.166 (10), p.2825-2828 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Extraction-based real-time reverse transcription quantitative polymerase chain reaction (RT-qPCR) is currently the “gold standard” in SARS-CoV-2 diagnostics. However, some extraction-free RT-qPCR techniques have recently been developed. In this study, we compared the sensitivity of traditional extraction-based, heated extraction-free, and unheated extraction-free RT-qPCR methods for SARS-CoV-2 detection in nasopharyngeal swabs from symptomatic individuals. The unheated extraction-free method showed perfect agreement with the standard extraction-based RT-qPCR. By contrast, the heat-treated technique was associated with an 8.2% false negativity rate. Unheated extraction-free RT-qPCR for the molecular diagnosis of SARS-CoV-2 is a valuable alternative to the traditional extraction-based methods and may accelerate turnaround times by about two hours. |
---|---|
ISSN: | 0304-8608 1432-8798 |
DOI: | 10.1007/s00705-021-05165-0 |