Atrioventricular synchronous pacing using leadless pacemaker in a heart transplant patient
We report the first leadless pacemaker (L-PM) providing atrioventricular synchronous pacing implanted into a heart transplant patient receiving chronic immunosuppressive therapy. The patient presented with syncope corresponding to sinus rhythm with high-grade atrioventricular block. Previously, L-PM...
Gespeichert in:
Veröffentlicht in: | BMJ case reports 2021-06, Vol.14 (6), p.e243365 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We report the first leadless pacemaker (L-PM) providing atrioventricular synchronous pacing implanted into a heart transplant patient receiving chronic immunosuppressive therapy. The patient presented with syncope corresponding to sinus rhythm with high-grade atrioventricular block. Previously, L-PMs provided only single-chamber ventricular sensing and pacing. A Micra AV lL-PM provides atrioventricular synchronous pacing by tracking mechanical atrial contraction. L-PMs, which now support broader indications, should be considered in patients at greater risk of infection. |
---|---|
ISSN: | 1757-790X 1757-790X |
DOI: | 10.1136/bcr-2021-243365 |