Custom Implants in TKA Provide No Substantial Benefit in Terms of Outcome Scores, Reoperation Risk, or Mean Alignment: A Systematic Review

Failure to accurately replicate the native anatomy and biomechanics of the knee has been suggested to contribute to dissatisfaction after TKA. Custom implants promise a personalized surgical approach, with the aim of improving patient satisfaction and pain as well as lowering revision rates. However...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinical orthopaedics and related research 2021-06, Vol.479 (6), p.1237-1249
Hauptverfasser: Beit Ner, Eran, Dosani, Saad, Biant, Leela C., Tawy, Gwenllian Fflur
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Failure to accurately replicate the native anatomy and biomechanics of the knee has been suggested to contribute to dissatisfaction after TKA. Custom implants promise a personalized surgical approach, with the aim of improving patient satisfaction and pain as well as lowering revision rates. However, some published research on custom TKA implants has found no clinically important improvements in postoperative validated outcomes scores, risks of revision or reoperation, and implant alignment. In the interest of helping to settle this controversy, a systematic review seems warranted. In this systematic review, we asked whether custom implants result in clinically important improvements over conventional off-the-shelf implants for anatomically uncomplicated primary TKA in terms of (1) validated outcomes scores, (2) the risk of revision or reoperation, and (3) implant alignment. The US National Library of Medicine (PubMed/Medline), Embase, Web of Science, and Cochrane Database of Systematic Reviews were systematically searched to identify publications from the past 10 years relevant to this review. Publications that compared the clinical outcome measures, number of revisions and reoperations, and radiological assessment of implant alignment of custom and standard implants with validated endpoints were eligible for inclusion. In the interest of capturing as much potentially relevant information as possible, we applied no requirement for minimum follow-up duration. Clinical outcomes were assessed using patient-reported outcome (PROM) scores including the Knee Society Score (KSS), Forgotten Joint Score, and Knee Injury and Osteoarthritis Outcome Score. The risk for revision or reoperation were evaluated by the number of early and late manipulations, debridement procedures, and replacement of one or more components. Implant alignment was compared using postoperative deviation from the neutral (0°) mechanical axis of the limb and each component and the posterior tibial slope. All qualified studies were retrospective, and all compared custom implants with standard implants. Data on 1510 patients were reviewed (749 with custom implants and 761 with off-the-shelf implants). The mean follow-up time ranged from 12 to 33 months. There was no apparent advantage to custom implants in terms of PROM scores. Of the five studies evaluating clinical outcomes, only one reported better KSS-Function scores at 3 months; two reported no difference, and two found inferior KSS scores.
ISSN:0009-921X