Comparable Pharmacokinetics, Safety, and Tolerability of Etrolizumab Administered by Prefilled Syringe or Autoinjector in a Randomized Trial in Healthy Volunteers

Introduction Etrolizumab is a novel, dual-action anti-β7 integrin antibody studied in phase 3 trials in patients with inflammatory bowel disease. An autoinjector (AI) is being developed in parallel to complement the prefilled syringe with needle safety device (PFS-NSD) for subcutaneous (SC) administ...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Advances in therapy 2021-05, Vol.38 (5), p.2418-2434
Hauptverfasser: Zhang, Wenhui, Tyrrell, Helen, Ding, Han Ting, Pulley, Jennifer, Boruvka, Audrey, Erickson, Rich, Abouhossein, Mariam, Ravanello, Renato, Tang, Meina Tao
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Introduction Etrolizumab is a novel, dual-action anti-β7 integrin antibody studied in phase 3 trials in patients with inflammatory bowel disease. An autoinjector (AI) is being developed in parallel to complement the prefilled syringe with needle safety device (PFS-NSD) for subcutaneous (SC) administration in these trials. Here we demonstrate the comparable pharmacokinetics, tolerability, and safety of both devices. Methods This randomized, open-label, two-part study in healthy participants evaluated the comparability of etrolizumab exposure between the AI and the PFS-NSD. Part 1 (pilot) involved a small number of participants, and initial results were used to finalize the design of the larger part 2 (pivotal) study. In both parts, participants were randomly assigned to receive a single SC dose of etrolizumab 105 mg by AI or PFS-NSD. Randomization was stratified by body weight. Primary pharmacokinetic outcomes were C max , AUC last , and AUC 0–inf . Results One hundred and eighty healthy participants (part 1, n  = 30; part 2, n  = 150) received a single SC dose of etrolizumab by AI or PFS-NSD. Primary pharmacokinetic results from part 1 supported modification of the part 2 study design. Results from part 2 demonstrated that etrolizumab exposure was equivalent between devices, with geometric mean ratios (GMRs) between AI and PFS-NSD of 102% (90% confidence interval [CI] 94.2–111) for C max , 98.0% (90% CI 89.3–107) for AUC last , and 97.6% (90% CI 88.6–107) for AUC 0–inf . Median t max and mean terminal t 1/2 were also similar between devices. GMRs and 90% CIs of all primary pharmacokinetic parameters were fully contained within the predefined equivalence limits (80–125%). Conclusion This pharmacokinetic study demonstrated that single SC injections of etrolizumab 105 mg using an AI or a PFS-NSD resulted in equivalent etrolizumab exposure and similar safety and tolerability in healthy participants. Taken together, these results support the use of an AI for etrolizumab administration. Trial Registration NCT02996019.
ISSN:0741-238X
1865-8652
DOI:10.1007/s12325-021-01661-6