Sheep can be used as animal model of regional myocardial remodeling and controllable work
Pacing the right heart has been shown to induce reversible conduction delay and subse-quent asymmetric remodeling of the left ventricle (LV) in dogs and pigs. Both species have disadvantages in animal experiments. Therefore the aim of this study was to develop a more feasible and easy-to-use animal...
Gespeichert in:
Veröffentlicht in: | Cardiology journal 2019-01, Vol.26 (4), p.375-384 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Pacing the right heart has been shown to induce reversible conduction delay and subse-quent asymmetric remodeling of the left ventricle (LV) in dogs and pigs. Both species have disadvantages in animal experiments. Therefore the aim of this study was to develop a more feasible and easy-to-use animal model in sheep.
Dual-chamber (DDD) pacemakers with epicardial leads on the right atrium and right ven-tricular free wall were implanted in 13 sheep. All animals underwent 8 weeks of chronic rapid pacing at 180 bpm. Reported observations were made at 110 bpm.
DDD pacing acutely induced a left bundle branch block (LBBB) - like pattern with almost doubling in QRS width and the appearance of a septal flash, indicating mechanical dyssynchrony. Atrial pacing (AAI) resulted in normal ventricular conduction and function. During 8 weeks of rapid DDD pacing, animals developed LV remodeling (confirmed with histology) with septal wall thinning (-30%, p < 0.05), lateral wall thickening (+22%, p < 0.05), LV volume increase (+32%, p < 0.05), decrease of LV ejection fraction (-31%, p < 0.05), and functional mitral regurgitation. After 8 weeks, segmental pressure-strain-loops, representing regional myocardial work, were recorded. Switching from AAI to DDD pacing decreased immediately work in the septum and increased it in the lateral wall (-69 and +41%, respectively, p < 0.05). Global LV stroke work and dP/dtmax decreased (-27% and -25%, respectively, p < 0.05).
This study presents the development a new sheep model with an asymmetrically remod-eled LV. Simple pacemaker programing allows direct modulation of regional myocardial function and work. This animal model provides a new and valuable alternative for canine or porcine models and has the potential to become instrumental for investigating regional function and loading conditions on regional LV remodeling. |
---|---|
ISSN: | 1897-5593 1897-5593 1898-018X |
DOI: | 10.5603/CJ.a2018.0007 |