Combining High Sensitivity and Dynamic Range: Wearable Thin-Film Composite Strain Sensors of Graphene, Ultrathin Palladium, and PEDOT:PSS
Wearable mechanical sensors have the potential to transform healthcare by enabling patient monitoring outside of the clinic. A critical challenge in the development of mechanicale.g., strainsensors is the combination of sensitivity, dynamic range, and robustness. This work describes a highly sensi...
Gespeichert in:
Veröffentlicht in: | ACS applied nano materials 2019-04, Vol.2 (4), p.2222-2229 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Wearable mechanical sensors have the potential to transform healthcare by enabling patient monitoring outside of the clinic. A critical challenge in the development of mechanicale.g., strainsensors is the combination of sensitivity, dynamic range, and robustness. This work describes a highly sensitive and robust wearable strain sensor composed of three layered materials: graphene, an ultrathin film of palladium, and highly plasticized PEDOT:PSS. The role of the graphene is to provide a conductive, manipulable substrate for the deposition of palladium. When deposited at low nominal thicknesses (∼8 nm), palladium forms a rough, granular film which is highly piezoresistive (i.e., the resistance increases with strain with high sensitivity). The dynamic range of these graphene/palladium films, however, is poor and can only be extended to ∼10% before failure. This fragility renders the films incompatible with wearable applications on stretchable substrates. To improve the working range of graphene/palladium strain sensors, a layer of highly plasticized PEDOT:PSS is used as a stretchable conductive binder. That is, the conductive polymer provides an alternative pathway for electrical conduction upon cracking of the palladium film and the graphene. The result was a strain sensor that possessed good sensitivity at low strains (0.001% engineering strain) but with a working range up to 86%. The piezoresistive performance can be optimized in a wearable device by sandwiching the conductive composite between a soft PDMS layer in contact with the skin and a harder layer at the air interface. When attached to the skin of the torso, the patch-like strain sensors were capable of detecting heartbeat (small strain) and respiration (large strain) simultaneously. This demonstration highlights the ability of the sensor to measure low and high strains in a single interpolated signal, which could be useful in monitoring, for example, obstructive sleep apnea with an unobtrusive device. |
---|---|
ISSN: | 2574-0970 2574-0970 |
DOI: | 10.1021/acsanm.9b00174 |