TBC: A simple algorithm to rule out abnormalities in electrocardiograms of patients with pacemakers
The aim of the study was to create a straightforward method to rule out abnormalities in electrocardiograms (ECGs) performed in patients with pacemakers. The TBC method screens the ECG for any of the following findings: Tachycardia with pacing spikes, Bradycardia without spikes and Chaos with spikes...
Gespeichert in:
Veröffentlicht in: | Cardiology journal 2020-05, Vol.27 (2), p.136-141 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The aim of the study was to create a straightforward method to rule out abnormalities in electrocardiograms (ECGs) performed in patients with pacemakers.
The TBC method screens the ECG for any of the following findings: Tachycardia with pacing spikes, Bradycardia without spikes and Chaos with spikes unrelated to QRS-T complexes. T was considered to advise for patient assessment and B and C to require referral for urgent pacemaker evaluation. The diagnostic accuracy of the algorithm was validated using a cohort of 151 ECGs with normal and dysfunctional pacemakers. The effect of the algorithm was then evaluated for diagnostic skills and management of patients with pacemakers by non-cardiologists, comparing their diagnostic accuracy before and after teaching the algorithm.
The TBC algorithm had a sensitivity of 86% and a specificity of 94% in diagnosing a malfunctioning pacemaker. The diagnostic skills and patient referral were significantly improved (74.8% vs. 89.5%, p < 0.001; and 57.4% vs. 83%, p < 0.001).
TBC is an easy to remember and apply method to rule out severe abnormalities in ECGs of patients with pacemakers. TBC algorithm has a very good diagnostic capability and is easily applied by non-expert physicians with good results. |
---|---|
ISSN: | 1897-5593 1898-018X 1897-5593 |
DOI: | 10.5603/CJ.a2018.0079 |