Whole-Brain Atrophy in Multiple Sclerosis Measured by Automated versus Semiautomated MR Imaging Segmentation

Semiautomated and automated methods are used to measure whole-brain atrophy in multiple sclerosis (MS), but their comparative reliability, sensitivity, and validity are unknown. Brain parenchymal fraction (BPF) was measured in patients with MS (n = 52) and healthy control subjects (n = 17) by four m...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:American journal of neuroradiology : AJNR 2004-06, Vol.25 (6), p.985-996
Hauptverfasser: Sharma, Jitendra, Sanfilipo, Michael P, Benedict, Ralph H. B, Weinstock-Guttman, Bianca, Munschauer, Frederick E., III, Bakshi, Rohit
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Semiautomated and automated methods are used to measure whole-brain atrophy in multiple sclerosis (MS), but their comparative reliability, sensitivity, and validity are unknown. Brain parenchymal fraction (BPF) was measured in patients with MS (n = 52) and healthy control subjects (n = 17) by four methods: semiautomated or automated segmentation and 2D or 3D pulse sequences. Linear measures of atrophy, whole-brain lesion volumes, and clinical data were used to explore validity. The 2D automated method yielded unreliable segmentation and was discarded. The three other BPF methods produced data that were highly intercorrelated and indistinguishable by analysis of variance. In the MS group, semiautomated (2D: 0.84 +/- 0.04, P