Good mid-term results with the trident peripheral self-locking cup: a clinical evaluation and migration measurement with EBRA
Introduction The most common cause of failure in total hip arthroplasty (THA) is aseptic loosening. Uncemented cup migration analysis by means of Einzel–Bild–Roentgen–Analyse (EBRA) has shown to be a good predictive indicator for early implant failure if the cup migrates more than 2 mm within 4 year...
Gespeichert in:
Veröffentlicht in: | Archives of orthopaedic and trauma surgery 2021-02, Vol.141 (2), p.327-332 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Introduction
The most common cause of failure in total hip arthroplasty (THA) is aseptic loosening. Uncemented cup migration analysis by means of Einzel–Bild–Roentgen–Analyse (EBRA) has shown to be a good predictive indicator for early implant failure if the cup migrates more than 2 mm within 4 years after surgery. In this study, we performed a migration analysis of an uncemented peripheral self-locking (PSL) press-fit cup after 4 years follow-up.
Materials and methods
We retrospectively reviewed all patients who received a trident PSL press-fit cup at our department between 2004 and 2017. A total of 636 patients were identified. As inclusion criteria for radiological analysis, a minimum follow-up of 2 years was defined. We reviewed medical histories and performed radiological analysis using EBRA software. EBRA measurements and statistical investigations were performed by two independent investigators.
Results
A total of 149 cups in 146 patients (female 82; male 64) met our inclusion criteria. Mean age at surgery was 65 years (33–89). We found a significant improvement in the WOMAC score pre- to postoperative (