Home-based SARS-CoV-2 lateral flow antigen testing in hospital workers
•46,503 home-based SARS-CoV-2 lateral flow tests were performed by hospital staff.•328 (0.7%) of tests were positive.•The positive predictive value was 96% and false positive rate 0.03%.•LFDs were less sensitive than PCR, but detected cases with higher viral loads.
Gespeichert in:
Veröffentlicht in: | The Journal of infection 2021-02, Vol.82 (2), p.282-327 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | •46,503 home-based SARS-CoV-2 lateral flow tests were performed by hospital staff.•328 (0.7%) of tests were positive.•The positive predictive value was 96% and false positive rate 0.03%.•LFDs were less sensitive than PCR, but detected cases with higher viral loads. |
---|---|
ISSN: | 0163-4453 1532-2742 |
DOI: | 10.1016/j.jinf.2021.01.008 |