Improved detection and precise relative quantification of the urinary cancer metabolite biomarkers – Creatine riboside, creatinine riboside, creatine and creatinine by UPLC-ESI-MS/MS: Application to the NCI-Maryland cohort population controls and lung cancer cases
[Display omitted] •A novel HILIC UPLC-MS/MS assay developed for the quantification of urinary cancer biomarkers CR, CNR, creatine, creatinine.•Urinary biomarkers were extracted from the NCI-MD cohort lung cancer case and population control patient’s biospecimens.•No matrix effect was observed during...
Gespeichert in:
Veröffentlicht in: | Journal of pharmaceutical and biomedical analysis 2020-11, Vol.191, p.113596-113596, Article 113596 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | [Display omitted]
•A novel HILIC UPLC-MS/MS assay developed for the quantification of urinary cancer biomarkers CR, CNR, creatine, creatinine.•Urinary biomarkers were extracted from the NCI-MD cohort lung cancer case and population control patient’s biospecimens.•No matrix effect was observed during method performance for urinary biomarkers detection and quantification in human serum.•This assay can be used in multiple laboratories for urinary biomarkers precise quantification at nM level in urine and serum.
Creatine riboside (CR) is a novel metabolite of cancer metabolism. It is a urinary diagnostic biomarker of lung and liver cancer risk and prognosis. The level of CR is highly positive correlated in tumor and urine indicating that it is derived from human lung and liver cancers. A precise and sensitive ultra-pressure liquid chromatography-tandem mass spectrometry (UPLC-ESI-MS/MS) method was developed and validated for simultaneous quantification of the noninvasive biomarker CR, along with creatinine riboside (CNR), and their precursors creatine and creatinine, utilizing the labeled internal standard creatine riboside-13C,15N2 (CR-13C,15N2). Chromatography was carried out on a hydrophilic interaction chromatography column under a gradient mobile phase condition. MRM transitions were monitored for CR (264.1 > 132.1, m/z), CNR (246.1 > 113.9, m/z), creatine (132.0 > 72.0, m/z), creatinine (114.0 > 85.8, m/z) and CR-13C,15N2 (267.1 > 134.9, m/z) with a 11.0 min run time in the positive mode ionization. The calibration plot of the method was linear over the concentration range of 4.50–10,000 nM. Method validation was performed according to regulatory guidelines established for sensitivity, selectivity, calibration curve, stability at different storage conditions, reinjection reproducibility, ruggedness with acceptable accuracy, and precision. This assay was applied for the quantification of CR along with CNR, creatine and creatinine in a subset of urine and serum samples from the National Cancer Institute – Maryland (NCI-MD) cohort population controls and lung cancer cases. It can be standardized and used in multiple laboratories for cancer diagnosis and determining the efficacy of cancer therapy and monitoring cancer recurrence. |
---|---|
ISSN: | 0731-7085 1873-264X |