Effects of the technique and drill design used during the osteotomy on the thermal and histological stimulation

The objective of our in vivo study was to compare the effects of the osteotomy on the thermal alterations, the bone healing and count of polymorphonuclear cells, comparing the drill design (cylindrical or conical) using continuous or intermittent movement. Twelve rabbits were used, which were made f...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Scientific reports 2020-11, Vol.10 (1), p.20737-20737, Article 20737
Hauptverfasser: Gehrke, Sergio Alexandre, Treichel, Tiago Luis Eliers, Aramburú Júnior, Jaime, de Aza, Piedad N., Prados-Frutos, Juan Carlos
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The objective of our in vivo study was to compare the effects of the osteotomy on the thermal alterations, the bone healing and count of polymorphonuclear cells, comparing the drill design (cylindrical or conical) using continuous or intermittent movement. Twelve rabbits were used, which were made four osteotomies (n = 2 per tibia) to simulate the surgical drilling sequence for the installation of a dental implant at 8 mm of length and regular diameter. Four groups were proposed: group G1, cylindrical drill with continuous movement; group G2, cylindrical drill with intermittent movement; group G3, conical drill with continuous movement; and, group G4, conical drill with intermittent movement. Thermal mean variation was 6.91 ± 1.4 °C in group 1, 4.30 ± 1.3 °C in group 2, 2.78 ± 0.6 °C in group 3, and 2.77 ± 0.7 °C in group 4. Whereas the mean area of new bone formation was 1.00 ± 0.3 mm 2 in group 1, 1.48 ± 0.3 mm 2 in group 2, 2.20 ± 0.4 mm 2 in group 3, and 2.43 ± 0.4 mm 2 in group 4. The mean count of polymorphonuclear cells, in the group 1 was 62.4 ± 5.9 cells, group 2 was 50.7 ± 4.2 cells, group 3 was 44.4 ± 3.7 cells, and group 4 was 42.4 ± 3.7 cells. The conical drill sequence produced a significantly smaller increase in temperature during both techniques (continuous and intermittent), more effective new bone formation and a smaller number of polymorphonuclear cells. During the osteotomy for the installation of implants, the professional must take to consider the drill design to perform a less traumatic surgical technique, which can improve and facilitate the healing of peri-implant tissues.
ISSN:2045-2322
2045-2322
DOI:10.1038/s41598-020-77762-z