Human amniotic membrane plug to promote failed macular hole closure

The failed macular hole is a full-thickness defect involving the fovea that fails to close despite 1 or more surgeries. While many surgical options have been proposed to manage it, none of these guarantee complete anatomical success and satisfactory visual recovery. We report postoperative outcomes...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Scientific reports 2020-10, Vol.10 (1), p.18264-18264, Article 18264
Hauptverfasser: Caporossi, Tomaso, Pacini, Bianca, Bacherini, Daniela, Barca, Francesco, Faraldi, Francesco, Rizzo, Stanislao
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The failed macular hole is a full-thickness defect involving the fovea that fails to close despite 1 or more surgeries. While many surgical options have been proposed to manage it, none of these guarantee complete anatomical success and satisfactory visual recovery. We report postoperative outcomes on 36 patients affected by failed macular hole, treated with a human amniotic membrane plug transplant. Follow-ups were performed with a standard ophthalmological examination and with advanced multimodal diagnostic imaging. Anatomical closure was achieved at 3 months in all patients. Mean best-corrected visual acuity improved statistically significantly at 6 months ( p  