The industrialization of ablation: a highly standardized and reproducible workflow for radiofrequency ablation of atrial fibrillation
Background or Purpose The purpose of this analysis was to report on efficacy of a standardized workflow for atrial fibrillation (AF) ablation using technology advances such as 3D imaging and contact force sensing in a real-world setting. Methods Consecutive AF ablations from 2014 to 2015 at a high-v...
Gespeichert in:
Veröffentlicht in: | Journal of interventional cardiac electrophysiology 2020-10, Vol.59 (1), p.21-27 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background or Purpose
The purpose of this analysis was to report on efficacy of a standardized workflow for atrial fibrillation (AF) ablation using technology advances such as 3D imaging and contact force sensing in a real-world setting.
Methods
Consecutive AF ablations from 2014 to 2015 at a high-volume site in Belgium were included. The workflow consisted of a pre-specified procedure sequence including 3D modeling followed by radiofrequency encircling of the pulmonary veins (25 W posterior wall, 35 W anterior wall) with a THERMOCOOL SMARTTOUCH® Catheter guided by CARTO VISITAG™ Module (2.5 mm/5 s stability, 50% > 7 g) and ablation index (targets: 550 anterior wall, 400 posterior wall). Efficiency endpoints were procedure time, fluoroscopy time, and radiation dose. The primary effectiveness endpoint was freedom from atrial arrhythmia recurrence.
Results
A total of 605 paroxysmal AF (PAF) and 182 persistent AF (PsAF) patients were followed for 436 ± 199 days. Mean procedure times were short (PAF: 96.1 ± 26.2 min; PsAF: 109.2 ± 35.6 min) with most procedures (90.6% PAF; 81.3% PsAF) completed in ≤ 120 min. Minimal fluoroscopy was utilized (PAF: 6.1 ± 3.8 min, 5.9 ± 3.4 Gy*cm
2
; PsAF: 6.9 ± 4.7 min, 7.4 ± 4.9 Gy*cm
2
). Freedom from atrial arrhythmia recurrence was higher for PAF than PsAF patients (OR: 2.0, 95% CI: 1.4–2.9,
p
= 0.0003), but adjusted mean rates were high in both groups (81.0% vs. 67.9%). Rates were adjusted for prior ablation and age (at 65 years).
Conclusion
AF ablation using a standardized workflow resulted in low procedure times and variability, with minimal fluoroscopy exposure. Long-term freedom from atrial arrhythmia recurrence was high in both PAF and PsAF populations. |
---|---|