Use of the variplex™ SARS-CoV-2 RT-LAMP as a rapid molecular assay to complement RT-PCR for COVID-19 diagnosis

•Rapid detection of SARS-CoV-2 by variplex™ RT-LAMP from respiratory samples.•Homogenization of samples using SL solution for testing without RNA elution.•Combination of RT-LAMP and RT-PCR increases diagnostic accuracy. Molecular assays based on reverse transcription-loop-mediated isothermal amplifi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of clinical virology 2020-11, Vol.132, p.104616-104616, Article 104616
Hauptverfasser: Rödel, Jürgen, Egerer, Renate, Suleyman, Aynur, Sommer-Schmid, Beatrice, Baier, Michael, Henke, Andreas, Edel, Birgit, Löffler, Bettina
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•Rapid detection of SARS-CoV-2 by variplex™ RT-LAMP from respiratory samples.•Homogenization of samples using SL solution for testing without RNA elution.•Combination of RT-LAMP and RT-PCR increases diagnostic accuracy. Molecular assays based on reverse transcription-loop-mediated isothermal amplification (RT-LAMP) may be useful for rapid diagnosis of the severe acute respiratory syndrome Coronavirus-2 (SARS-CoV-2) because of the easy performance and the option to bypass RNA extraction. This study was designed to evaluate the clinical performance of the CE-labeled variplexTM real time SARS-CoV-2 RT-LAMP assay in comparison to commercial RT-PCRs. RNA extracted from pharyngeal swabs was tested by variplex™ RT-LAMP and Corman’s LightMix™ E gene RT-PCR as reference. Samples of respiratory secretions from Coronavirus infection disease (COVID-19) and negative control patients were analyzed by variplex™ without RNA extraction and tested in parallel with the Allplex™ and VIASURE BD MAX RT-PCRs. Using isolated RNA variplex™ RT-LAMP showed a sensitivity of 75 % compared to LightMix E gene RT-PCR but contrary to the latter it produced no false-positive results. For the evaluation of samples from respiratory secretions concordance analysis showed only a moderate agreement between the variplex™ RT-LAMP conducted on unprocessed samples and Allplex™ and VIASURE RT-PCRs (Cohen’s κ ranging from 0.52−0.56). Using the approach to define a sample as true-positive when at least two assays gave a positive result the clinical sensitivities were as follows: 76.3 % for variplex™, 84.2 % for Allplex™ and 68.4 % for VIASURE. However, when results of RT-PCR and RT-LAMP were combined diagnostic sensitivity was increased to 92–100 %. The variplex RT-LAMP may serve as a rapid test to be combined with a RT-PCR assay to increase the diagnostic accuracy in patients with suspected COVID-19 infection.
ISSN:1386-6532
1873-5967
DOI:10.1016/j.jcv.2020.104616