Cyberknife, Helical Tomotherapy and Rapid Arc SIB-SBRT Treatment Plan Comparison for Carcinoma Prostate
This study was conducted to dosimetrically compare plan quality of Simultaneous Integrated Boost - Stereotactic Body Radiotherapy (SIB-SBRT) generated for different techniques such as Cyberknife (CK), Helical Tomotherapy (HT) and RapidArc (RA) for carcinoma prostate with same treatment margins. SIB-...
Gespeichert in:
Veröffentlicht in: | Asian Pacific Journal of Cancer Prevention 2020-04, Vol.21 (4), p.1149-1154 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This study was conducted to dosimetrically compare plan quality of Simultaneous Integrated Boost - Stereotactic Body Radiotherapy (SIB-SBRT) generated for different techniques such as Cyberknife (CK), Helical Tomotherapy (HT) and RapidArc (RA) for carcinoma prostate with same treatment margins.
SIB-SBRT plans were generated for CK, HT and RA for thirteen CT data sets. The dose prescription was 45Gy in 5 fractions to GTV45 and 37.5Gy in 5 fractions to PTV37.5. The plan quality evaluation of the three techniques was done by comparing the DVH parameters, conformity index (CI) and gradient index (GI). For OAR's mean, maximum dose and dose volumes were compared for bladder, rectum and bilateral femoral heads. The number of Monitor Units (MU) delivered and Beam-on time (BOT) were also compared.
D2%, D50% and DMean to GTV45 was significantly higher in the CK compared to HT and RA (CK vs HT: p values, |
---|---|
ISSN: | 2476-762X 1513-7368 2476-762X |
DOI: | 10.31557/apjcp.2020.21.4.1149 |