Organizational Factors Associated with Sepsis Bundle Compliance: A Nationwide Study

Sepsis is one of the leading causes of mortality in the United States (U.S.), accounting for over 220 000 deaths annually. To address the issue of mortality, the Centers for Medicare and Medicaid Services (CMS) launched a core measure with an associated clinical bundle. This measure requires complet...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Health services research 2020-08, Vol.55 (S1), p.82-83
Hauptverfasser: Peach, B.C., Ng, B.P.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Sepsis is one of the leading causes of mortality in the United States (U.S.), accounting for over 220 000 deaths annually. To address the issue of mortality, the Centers for Medicare and Medicaid Services (CMS) launched a core measure with an associated clinical bundle. This measure requires completion of time‐sensitive bundled interventions (eg, fluid resuscitation, antibiotics). Completion of these interventions is known to improve the odds of survival. CMS reimbursement is not currently tied to a certain compliance level; however, it is under consideration. Hospitals’ compliance with the bundle is publicly reported as the SEP‐1 measure. The objective of this study was to examine which hospital organizational factors were associated with high and low compliance with the SEP‐1 measure. This study used a cross‐sectional design with 2017 hospital‐level data from the CMS Timely and Effective Care dataset, and the American Hospital Association (AHA)’s Annual Survey. A multivariate logistic regression with outcome variable of hospital compliance (high/low) with the SEP‐1 measure (0 = less than overall average on SEP‐1 score; 1 = greater than overall average) was performed. Control variables included: number of beds (250), teaching status (teaching, nonteaching), technology level (high, low), intensive care unit (ICU) beds (none, 1‐4, 5‐14, 15‐29, 30 or more), ownership (government, non‐for‐profit, for‐profit), sepsis case volume (0‐100, 101‐200, 201 or more), nurse hours per patient day, and Magnet certification status (yes/no). The study included 2429 acute care, nonspecialty adult U.S. hospitals. Hospitals were excluded if they did not complete the AHA survey. The overall average SEP1 score was 48.9% on a 0‐100 scale. Of 2429 hospitals, 49% were high compliance hospitals, and 51% were low compliance. Factors associated with increased odds of compliance included: for‐profit ownership (OR = 2.48; 95% CI = 1.78‐3.44; P  
ISSN:0017-9124
1475-6773