Evaluation of the ceiling levels of ortho‐phthalaldehyde exposure among health care workers engaged in endoscope disinfection: A new methodology using video‐exposure monitoring

Objectives The present study aimed to develop a method for measuring the ceiling level of ortho‐phthalaldehyde (OPA) exposure and evaluate the ceiling levels of OPA exposure among health care workers who handle disinfectant solutions containing OPA for the disinfection of endoscopes. Methods The stu...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of occupational health 2020-01, Vol.62 (1), p.e12139-n/a
Hauptverfasser: Yamamoto, Shinobu, Hachiya, Yuriko, Yuasa, Eri, Takeuchi, Akito, Ishidao, Toru, Mihara, Mitsuhisa, Terauchi, Yasuhiro, Ichiba, Masayoshi, Hori, Hajime
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Objectives The present study aimed to develop a method for measuring the ceiling level of ortho‐phthalaldehyde (OPA) exposure and evaluate the ceiling levels of OPA exposure among health care workers who handle disinfectant solutions containing OPA for the disinfection of endoscopes. Methods The study consisted of a preliminary survey and main survey. In the preliminary survey, processes involving high‐concentration exposure to OPA were identified by video‐exposure monitoring (VEM). In the main survey, the ceiling levels of OPA exposure for high‐concentration exposure processes identified from the results of the preliminary survey were determined using a measuring method combining sampling using a 2,4‐dinitrophenylhydrazine‐silica cartridge and analysis by high‐performance liquid chromatography tandem mass spectrometry. Results In the preliminary survey, seven processes involving high‐concentration exposure to OPA were identified by VEM. The duration of each process was short, lasting from 20 seconds to a few minutes. In the main survey, the OPA concentrations for the identified high‐concentration exposure processes ranged from 1.18 to 4.49 ppb, which markedly exceeded the threshold limit value ceiling (TLV‐C) of 0.1 ppb recommended by the American Conference of Governmental Industrial Hygienists. Conclusions The method for measuring the ceiling level of OPA exposure was established using VEM and the highly sensitive method of chemical analysis; and we successfully evaluated the ceiling levels of OPA exposure among health care workers engaged in endoscope disinfection. This approach can also be applied to other chemical substances with recommended TLV‐Cs, and important information for reducing exposure can thus be obtained.
ISSN:1348-9585
1341-9145
1348-9585
DOI:10.1002/1348-9585.12139