Reliability and Validity of the Japanese Version of the Mini-balance Evaluation Systems Test in Patients with Subacute Stroke
Objective: The objective of the current study was to evaluate the reliability and validity of the Japanese version of the Mini-Balance Evaluation Systems Test (J-Mini-BESTest) in patients with subacute stroke. Methods: Eighteen patients who had suffered a first hemiplegic stroke (mean age, 59.1 ± 27...
Gespeichert in:
Veröffentlicht in: | Progress in Rehabilitation Medicine 2018, Vol.3, pp.20180015 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Objective: The objective of the current study was to evaluate the reliability and validity of the Japanese version of the Mini-Balance Evaluation Systems Test (J-Mini-BESTest) in patients with subacute stroke. Methods: Eighteen patients who had suffered a first hemiplegic stroke (mean age, 59.1 ± 27.0 years) and had been admitted to convalescent rehabilitation wards were enrolled. The J-Mini-BESTest, the Berg Balance Scale (BBS), and the functional reach test (FRT) were used to assess balance. Four physical therapists (PTs) observed and scored the J-Mini-BESTest while another PT conducted the test. The interrater reliability of the J-Mini-BESTest was assessed using intraclass correlation coefficients (ICC[2,1]) for the total and section scores, and kappa statistics for each item. Internal consistency of the five raters was assessed using Cronbach’s alpha. Concurrent validity of the J-Mini-BESTest was assessed against the BBS and FRT using Spearman’s correlation coefficients. Results: The ICC[2,1] of the total and section scores were 0.90 (95% confidence interval: 0.81–0.95) and 0.63–0.85, respectively. Cronbach’s alphas were 0.80–0.87. The kappa statistics were 0.47–1.00. The scores of the J-Mini-BESTest were significantly correlated with those of the BBS (rho=0.66, p=0.006) but not with those of the FRT (rho=–0.36, p=0.189). Conclusion: The J-Mini-BESTest showed excellent inter-rater reliability and internal consistency. Although the J-Mini-BESTest was not correlated with the FRT, it was significantly correlated with the BBS. The J-Mini-BESTest is a reliable and valid tool for evaluating dynamic balance in patients with subacute stroke. |
---|---|
ISSN: | 2432-1354 2432-1354 |
DOI: | 10.2490/prm.20180015 |