Biomechanical Analysis of Plate Fixation Compared With Various Screw Configurations for Use in the Latarjet Procedure

Background: The biomechanical properties of coracoid fixation with a miniplate during the Latarjet procedure have not been described. Purpose: To determine the biomechanical properties of miniplate fixation for the Latarjet procedure compared with various screw fixation configurations. Study Design:...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Orthopaedic journal of sports medicine 2020-07, Vol.8 (7), p.2325967120931399-2325967120931399
Hauptverfasser: Frank, Rachel M., Roth, Martina, Wijdicks, Coen Abel, Fischer, Nicole, Costantini, Alberto, Di Giacomo, Giovanni, Romeo, Anthony A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background: The biomechanical properties of coracoid fixation with a miniplate during the Latarjet procedure have not been described. Purpose: To determine the biomechanical properties of miniplate fixation for the Latarjet procedure compared with various screw fixation configurations. Study Design: Controlled laboratory study. Methods: A total of 8 groups (n = 5 specimens per group) were tested at a screw insertion angle of 0°: (1) 3.75-mm single screw, (2) 3.75-mm double screw, (3) 3.75-mm double screw with washers, (4) 3.75-mm double screw with a miniplate, (5) 4.00-mm single screw, (6) 4.00-mm double screw, (7) 4.00-mm double screw with washers, and (8) 4.00-mm double screw with a miniplate. In addition, similar to groups 1 to 3 and 5 to 7, there were 30 additional specimens (n = 5 per group) tested at a screw insertion angle of 15° (groups 9-14). To maintain specimen uniformity, rigid polyurethane foam blocks were used. Testing parameters included a preload of 214 N for 10 seconds, cyclical loading from 184 to 736 N at 1 Hz for 100 cycles, and failure loading at a rate of 15 mm/min until 10 mm of displacement or specimen failure occurred. Results: All single-screw constructs and 77% of 15° screw constructs failed before the completion of cyclical loading. Across all groups, group 8 (4.00-mm double screw with miniplate) demonstrated the highest maximum failure load (P < .001). There were no differences in failure loads among specimens with single-screw fixation (groups 1, 5, 9, and 12; P > .05). All specimens in groups 9, 10, 11, 12, 13, and 14 (insertion angle of 15°) had significantly lower maximum failure loads compared with specimens in groups 2, 3, 4, 6, 7, and 8 (insertion angle of 0°) (P < .001 for all). Conclusion: These results indicate significantly superior failure loads with the miniplate compared with all other constructs. Across all fixation techniques and screw sizes, constructs with screws inserted at 0° performed better than constructs with screws inserted at 15°. Clinical Relevance: The use of a miniplate for coracoid fixation during the Latarjet procedure may provide a more durable construct for the high-demand contact athlete.
ISSN:2325-9671
2325-9671
DOI:10.1177/2325967120931399