Characterization and validation of an in vivo confocal Raman spectroscopy led tri‐method approach in the evaluation of the lip barrier
Background/Aim It was the aim to establish and validate in vivo confocal Raman spectroscopy for characterization of the lip barrier in conjunction with transepidermal water loss (TEWL) and skin capacitance assessments. For the first time in vivo, barrier‐relevant components of the lip (derived, natu...
Gespeichert in:
Veröffentlicht in: | Skin research and technology 2020-05, Vol.26 (3), p.390-397 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background/Aim
It was the aim to establish and validate in vivo confocal Raman spectroscopy for characterization of the lip barrier in conjunction with transepidermal water loss (TEWL) and skin capacitance assessments. For the first time in vivo, barrier‐relevant components of the lip (derived, natural moisturizing factors (NMFs) and ceramides are described.
Methods
In 32 healthy volunteers, a dental tongue fixation device was inserted to prevent both voluntary and involuntary lip moisturization during measurements. Seventeen individual parameters relating to water, ceramide, and NMF content were assessed via Raman spectroscopy. Additionally, corneometry and TEWL were measured. To give a guidance for the required volunteer group size of future lip barrier studies for all test parameters, coefficients of variation (CV) were calculated and plots showing the required sample size for a given percentage treatment effect.
Results
Raman spectroscopy assessed parameters on the lower lip comprehensively characterized the state of the lip barrier. Parameter variability was sufficiently low to corroborate changes in most parameters using relatively small study populations.
Conclusions
Lip skin is comparatively well hydrated. Biophysical measurement of the lip barrier function is a challenge, as unconscious licking of the lower lip has to be prevented. In vivo confocal Raman spectroscopy provides insightful parameters for the characterization of the lip barrier and sufficiently low inter‐individual variability to assess relatively small parameter changes employing relatively few study subjects. Differences at the molecular level and at a high spatial resolution are detectable, and these insights might provide a breakthrough in the evaluation of lip barrier function and developing solutions for lip care. |
---|---|
ISSN: | 0909-752X 1600-0846 |
DOI: | 10.1111/srt.12814 |