Insertion of a 1.9F central venous catheter via the internal jugular vein in neonates
This study aimed to develop a technique for placing a 1.9 French (F) central venous catheter in the internal jugular vein of newborns. In this retrospective study, punctures were performed with a modified ultrasound-guided Seldinger technique with 57 1.9F catheters in 48 newborns. Punctures were per...
Gespeichert in:
Veröffentlicht in: | Journal of international medical research 2020-06, Vol.48 (6), p.300060520925380-300060520925380 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This study aimed to develop a technique for placing a 1.9 French (F) central venous catheter in the internal jugular vein of newborns.
In this retrospective study, punctures were performed with a modified ultrasound-guided Seldinger technique with 57 1.9F catheters in 48 newborns. Punctures were performed in the right internal jugular vein in 43 (75.4%) patients and in the left internal jugular vein in 14 (24.6%) patients.
We included 33 (57.9%) boys and 24 (42.1%) girls, aged a median 38 days (range, 2-135 days). The puncture success rate was 100%. Catheterization duration was a median 14 days (range, 1-70 days). Among the catheters, 94.1% were removed after completion of therapy or upon death. Fifty-three (93%) patients experienced no complication, whereas a small amount of bleeding was observed in 2 (3.5%) patients, inflammation of puncture in 1 (1.8%) patient, and occlusion in 1 (1.8%) patient. The method of placement of 1.9F catheters in the internal jugular vein of newborns had a high success rate, with minimal trauma and few complications.
Our method of placing a 1.9F central venous catheter in the internal jugular vein is suggested for level III to VI neonatal intensive care units. |
---|---|
ISSN: | 0300-0605 1473-2300 |