Diagnostic Performance of CT and Reverse Transcriptase Polymerase Chain Reaction for Coronavirus Disease 2019: A Meta-Analysis
Background Recent studies have suggested that chest CT scans could be used as a primary screening or diagnostic tool for coronavirus disease 2019 (COVID-19) in epidemic areas. Purpose To perform a meta-analysis to evaluate diagnostic performance measures, including predictive values of chest CT and...
Gespeichert in:
Veröffentlicht in: | Radiology 2020-09, Vol.296 (3), p.E145-E155 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background Recent studies have suggested that chest CT scans could be used as a primary screening or diagnostic tool for coronavirus disease 2019 (COVID-19) in epidemic areas. Purpose To perform a meta-analysis to evaluate diagnostic performance measures, including predictive values of chest CT and initial reverse transcriptase polymerase chain reaction (RT-PCR). Materials and Methods Medline and Embase were searched from January 1, 2020, to April 3, 2020, for studies on COVID-19 that reported the sensitivity, specificity, or both of CT scans, RT-PCR assays, or both. The pooled sensitivity and specificity were estimated by using random-effects models. The actual prevalence (ie, the proportion of confirmed patients among those tested) in eight countries was obtained from web sources, and the predictive values were calculated. Meta-regression was performed to reveal the effect of potential explanatory factors on the diagnostic performance measures. Results The pooled sensitivity was 94% (95% confidence interval [CI]: 91%, 96%;
= 95%) for chest CT and 89% (95% CI: 81%, 94%;
= 90%) for RT-PCR. The pooled specificity was 37% (95% CI: 26%, 50%;
= 83%) for chest CT. The prevalence of COVID-19 outside China ranged from 1.0% to 22.9%. For chest CT scans, the positive predictive value (PPV) ranged from 1.5% to 30.7%, and the negative predictive value (NPV) ranged from 95.4% to 99.8%. For RT-PCR, the PPV ranged from 47.3% to 96.4%, whereas the NPV ranged from 96.8% to 99.9%. The sensitivity of CT was affected by the distribution of disease severity, the proportion of patients with comorbidities, and the proportion of asymptomatic patients (all
< .05). The sensitivity of RT-PCR was negatively associated with the proportion of elderly patients (
= .01). Conclusion Outside of China where there is a low prevalence of coronavirus disease 2019 (range, 1%-22.9%), chest CT screening of patients with suspected disease had low positive predictive value (range, 1.5%-30.7%). © RSNA, 2020 |
---|---|
ISSN: | 0033-8419 1527-1315 |
DOI: | 10.1148/radiol.2020201343 |