An Optical Surface Applicator for Intraoperative Photodynamic Therapy

Background and Objectives Intraoperative photodynamic therapy (IO‐PDT) is typically administered by a handheld light source. This can result in uncontrolled distribution of light irradiance that impacts tissue and tumor response to photodynamic therapy. The objective of this work was to characterize...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Lasers in surgery and medicine 2020-07, Vol.52 (6), p.523-529
Hauptverfasser: Chamberlain, Sarah, Bellnier, David, Yendamuri, Sai, Lindenmann, Joerg, Demmy, Todd, Nwogu, Chukwumere, Ramer, Max, Tworek, Larry, Oakley, Emily, Mallory, Matthew, Carlsen, Lindsey, Sexton, Sandra, Curtin, Leslie, Shafirstein, Gal
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background and Objectives Intraoperative photodynamic therapy (IO‐PDT) is typically administered by a handheld light source. This can result in uncontrolled distribution of light irradiance that impacts tissue and tumor response to photodynamic therapy. The objective of this work was to characterize a novel optical surface applicator (OSA) designed to administer controlled light irradiance in IO‐PDT. Study Design/Materials and Methods An OSA was constructed from a flexible silicone mesh applicator with multiple cylindrically diffusing optical fibers (CDF) placed into channels of the silicone. Light irradiance distribution, at 665 nm, was evaluated on the OSA surface and after passage through solid tissue‐mimicking optical phantoms by measurements from a multi‐channel dosimetry system. As a proof of concept, the light administration of the OSA was tested in a pilot study by conducting a feasibility and performance test with 665‐nm laser light to activate 2‐(1′‐hexyloxyethyl) pyropheophorbide‐a (HPPH) in the thoracic cavity of adult swine. Results At the OSA surface, the irradiance distribution was non‐uniform, ranging from 128 to 346 mW/cm2. However, in the tissue‐mimicking phantoms, beam uniformity improved markedly, with irradiance ranges of 39–153, 33–87, and 12–28 mW/cm2 measured at phantom thicknesses of 3, 5, and 10 mm, respectively. The OSA safely delivered the prescribed light dose to the thoracic cavities of four swine. Conclusions The OSA can provide predictable light irradiances for administering a well‐defined and potentially effective therapeutic light in IO‐PDT. Lasers Surg. Med. © 2019 Wiley Periodicals, Inc.
ISSN:0196-8092
1096-9101
DOI:10.1002/lsm.23168