Urine Steroid Metabolomics as a Novel Tool for Detection of Recurrent Adrenocortical Carcinoma
Abstract Context Urine steroid metabolomics, combining mass spectrometry-based steroid profiling and machine learning, has been described as a novel diagnostic tool for detection of adrenocortical carcinoma (ACC). Objective, Design, Setting This proof-of-concept study evaluated the performance of ur...
Gespeichert in:
Veröffentlicht in: | The journal of clinical endocrinology and metabolism 2020-03, Vol.105 (3), p.e307-e318 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Abstract
Context
Urine steroid metabolomics, combining mass spectrometry-based steroid profiling and machine learning, has been described as a novel diagnostic tool for detection of adrenocortical carcinoma (ACC).
Objective, Design, Setting
This proof-of-concept study evaluated the performance of urine steroid metabolomics as a tool for postoperative recurrence detection after microscopically complete (R0) resection of ACC.
Patients and Methods
135 patients from 14 clinical centers provided postoperative urine samples, which were analyzed by gas chromatography–mass spectrometry. We assessed the utility of these urine steroid profiles in detecting ACC recurrence, either when interpreted by expert clinicians or when analyzed by random forest, a machine learning-based classifier. Radiological recurrence detection served as the reference standard.
Results
Imaging detected recurrent disease in 42 of 135 patients; 32 had provided pre- and post-recurrence urine samples. 39 patients remained disease-free for ≥3 years. The urine “steroid fingerprint” at recurrence resembled that observed before R0 resection in the majority of cases. Review of longitudinally collected urine steroid profiles by 3 blinded experts detected recurrence by the time of radiological diagnosis in 50% to 72% of cases, improving to 69% to 92%, if a preoperative urine steroid result was available. Recurrence detection by steroid profiling preceded detection by imaging by more than 2 months in 22% to 39% of patients. Specificities varied considerably, ranging from 61% to 97%. The computational classifier detected ACC recurrence with superior accuracy (sensitivity = specificity = 81%).
Conclusion
Urine steroid metabolomics is a promising tool for postoperative recurrence detection in ACC; availability of a preoperative urine considerably improves the ability to detect ACC recurrence. |
---|---|
ISSN: | 0021-972X 1945-7197 |
DOI: | 10.1210/clinem/dgz141 |