The association between the ultrasonography TIRADS classification system and surgical pathology among indeterminate thyroid nodules

A high proportion of cytologically indeterminate, Afirma-suspicious thyroid nodules are benign. The Thyroid Imaging Reporting and Data System was proposed by the American College of Radiology in 2015 to determine appropriate management of thyroid nodules in a standardized fashion. Our aim was to det...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Surgery 2019-01, Vol.165 (1), p.69-74
Hauptverfasser: Sahli, Zeyad T, Karipineni, Farah, Hang, Jen-Fan, Canner, Joseph K, Mathur, Aarti, Prescott, Jason D, Sheth, Sheila, Ali, Syed Z, Zeiger, Martha A
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A high proportion of cytologically indeterminate, Afirma-suspicious thyroid nodules are benign. The Thyroid Imaging Reporting and Data System was proposed by the American College of Radiology in 2015 to determine appropriate management of thyroid nodules in a standardized fashion. Our aim was to determine the diagnostic value of the Thyroid Imaging Reporting and Data System in cytologically indeterminate and Afirma-suspicious nodules. We retrospectively queried cytopathology archives for retrospectively for thyroid fine-needle aspiration specimens obtained between February 2012 and September 2016 that were associated with the following: (1) indeterminate diagnosis, (2) ultrasonographic imaging at our institution, (3) an Afirma Gene Expression Classifier–suspicious result, and (4) surgery at our institution. We then calculated the diagnostic value of the Thyroid Imaging Reporting and Data System in predicting surgical pathology. Our cohort consisted of 133 nodules among 131 patients who underwent thyroid surgery for cytologically indeterminate, Afirma-suspicious nodules. A total of 9 nodules (6.8%) were assigned TR2 “not suspicious,” 25 (18.8%) TR3 “mildly suspicious,” 81 (60.9%) TR4 “moderately suspicious,” and 18 (13.5%) TR5 “highly suspicious.” Among our cohort, the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of the Thyroid Imaging Reporting and Data System was 71.4%, 38.1%, 40.2%, 69.6%, and 50.4%, respectively. Among cytologically indeterminate and Afirma-suspicious nodules, the Thyroid Imaging and Reporting and Data System was a poor predictor of final surgical pathology. Additional prospective studies are needed to validate these findings.
ISSN:0039-6060
1532-7361
DOI:10.1016/j.surg.2018.04.094