Electroretinographic recordings with skin electrodes to assess effects of vitrectomy with gas tamponade on eyes with rhegmatogenous retinal detachment
The purpose of this study was to evaluate the retinal function by electroretinograms (ERGs) recorded with the RETeval system using skin electrodes after pars plana vitrectomy (PPV) with gas tamponade in eyes with a rhegmatogeneous retinal detachment (RRD). Flicker ERGs were recorded from 17 eyes wit...
Gespeichert in:
Veröffentlicht in: | Scientific reports 2019-12, Vol.9 (1), p.19948-19948, Article 19948 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The purpose of this study was to evaluate the retinal function by electroretinograms (ERGs) recorded with the RETeval system using skin electrodes after pars plana vitrectomy (PPV) with gas tamponade in eyes with a rhegmatogeneous retinal detachment (RRD). Flicker ERGs were recorded from 17 eyes with an RRD before (baseline), within 2 weeks after the PPV when the size of the tamponade gas was approximately one-half of the vitreous cavity (P1), and when the gas had been completely absorbed (P2). The amplitudes of the flicker ERGs at each phase were compared to that at the baseline. The median (25th, 75th percentile) of the amplitude was 10.0 µV (5.5, 13.0 µV) at the baseline, 11.7 µV at P1 (7.8, 14.8 µV;
P
= 0.003), and 17.1 µV at P2 (11.7 23.3 μV;
P
|
---|---|
ISSN: | 2045-2322 2045-2322 |