Performance of an atrial fibrillation detection algorithm using continuous pulse wave monitoring

Background Detecting asymptomatic and undiagnosed atrial fibrillation (AF) is increasingly important. Recently, we developed a wristwatch‐based pulse wave monitor (PWM; Seiko Epson, Japan) capable of long‐term recording, with an automatic diagnosis algorithm that uses frequency‐based pulse wave anal...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Annals of noninvasive electrocardiology 2019-03, Vol.24 (2), p.e12615-n/a
Hauptverfasser: Kashiwa, Asami, Koyama, Fumio, Miyamoto, Koji, Kamakura, Tsukasa, Wada, Mitsuru, Yamagata, Kenichiro, Ishibashi, Kohei, Inoue, Yuko, Okamura, Hideo, Nagase, Satoshi, Noda, Takashi, Aiba, Takeshi, Watanabe, Shinichiro, Goto, Akihiro, Yasuda, Satoshi, Kusano, Kengo
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background Detecting asymptomatic and undiagnosed atrial fibrillation (AF) is increasingly important. Recently, we developed a wristwatch‐based pulse wave monitor (PWM; Seiko Epson, Japan) capable of long‐term recording, with an automatic diagnosis algorithm that uses frequency‐based pulse wave analysis. The aim of this study was to evaluate the validity of continuous pulse wave monitoring for detection of AF. Methods During the electrophysiological study (EPS) in patients with AF, simultaneous pulse wave monitoring and Holter electrocardiograms (ECG) were recorded (n = 136, mean age 62.7 ± 10.9 years). The diagnostic accuracy of the PWM for AF was compared to the Holter ECG diagnosis. Standard performance metrics (sensitivity [Se], specificity [Sp], positive predictive value [PPV], and negative predictive value [NPV]) were calculated. The duration‐based measurements were based on the diagnosis concordance ratios for the duration of time between diagnosis detected by the PWM and true diagnosis by the Holter ECG (AF or not AF). The episode‐based performance metrics were based on the proportion of episodes appropriately detected with the PWM relative to episodes determined by the Holter ECG. Results The total recording time was 1,542,770 s (AF: 270,945 s). A high diagnostic Sp (patient average: 96.4%, cumulative: 97.7%) and NPV (patient average: 95.1%, cumulative: 96.8%) were obtained in the duration‐based results. In the episode‐based metrics, all indices significantly improved with longer AF episode durations. Conclusions Continuous pulse wave monitoring can provide accurate and dependable information to aid in AF diagnosis. A high validity in confirming freedom from AF was shown by a high NPV.
ISSN:1082-720X
1542-474X
DOI:10.1111/anec.12615