Comparing D-bar and common regularization-based methods for electrical impedance tomography

Objective: To compare D-bar difference reconstruction with regularized linear reconstruction in electrical impedance tomography. Approach: A standard regularized linear approach using a Laplacian penalty and the GREIT method for comparison to the D-bar difference images. Simulated data was generated...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Physiological measurement 2019-04, Vol.40 (4), p.044004-044004
Hauptverfasser: Hamilton, S J, Lionheart, W R B, Adler, A
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Objective: To compare D-bar difference reconstruction with regularized linear reconstruction in electrical impedance tomography. Approach: A standard regularized linear approach using a Laplacian penalty and the GREIT method for comparison to the D-bar difference images. Simulated data was generated using a circular phantom with small objects, as well as a 'Pac-Man' shaped conductivity target. An L-curve method was used for parameter selection in both D-bar and the regularized methods. Main results: We found that the D-bar method had a more position independent point spread function, was less sensitive to errors in electrode position and behaved differently with respect to additive noise than the regularized methods. Significance: The results allow a novel pathway between traditional and D-bar algorithm comparison.