Four‐year results of a minimally invasive transscleral glaucoma gel stent implantation in a prospective multi‐centre study

Importance The transscleral XEN Glaucoma Gel Microstent (XEN‐GGM, Allergan Plc., Parsippany, New Jersey) is implanted by a minimally invasive ab interno technique. Background The present study aims to assess the long‐term clinical outcomes in patients after XEN‐GGM implantation. Design This prospect...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinical & experimental ophthalmology 2019-07, Vol.47 (5), p.581-587
Hauptverfasser: Lenzhofer, Markus, Kersten‐Gomez, Inga, Sheybani, Arsham, Gulamhusein, Husayn, Strohmaier, Clemens, Hohensinn, Melchior, Burkhard Dick, H, Hitzl, Wolfgang, Eisenkopf, Lisa, Sedarous, Fady, Ahmed, Iqbal I., Reitsamer, Herbert A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Importance The transscleral XEN Glaucoma Gel Microstent (XEN‐GGM, Allergan Plc., Parsippany, New Jersey) is implanted by a minimally invasive ab interno technique. Background The present study aims to assess the long‐term clinical outcomes in patients after XEN‐GGM implantation. Design This prospective, non‐randomized, multi‐centred study was conducted in three countries (Austria, Canada and Germany). Participants Sixty‐four consecutive eyes of 64 patients with open angle glaucoma received the XEN‐GGM (63 μm) without Mitomycin C. Thirty‐five (55%) were solo procedures, and 29 (45%) were combined with cataract surgery. Methods Visits were planned at baseline, 6 months, 1, 2, 3 and 4 years postoperatively. Main Outcome Measures The main outcome measures were mean intraocular pressure (IOP), mean number of IOP lowering medication. Secondary outcome parameters were: visual acuity, visual fields and complete surgical failure (defined as presence of a secondary IOP lowering procedure or loss of light perception) at 4 years, postoperatively. Results Mean best‐medicated baseline IOP was 22.5 ± 4.2 mmHg and decreased significantly to 13.4 ± 3.1 mmHg 4 years postoperatively (−40%, n = 34, P < 0.001). Mean number of IOP lowering medication decreased significantly from 2.4 ± 1.3 preoperatively to 1.2 ± 1.3 (−50%, n = 34, P < 0.001) postoperatively. Visual field mean deviation showed no significant change between preoperative and postoperative examinations. Complete surgical failure rate per year was 10%. Conclusions and Relevance The XEN‐GGM resulted in lower IOP and a reduction in medications from baseline over 4 years of follow‐up. There was no detectable decrease in visual fields over the study. The surgical failure rate is comparable to other filtration surgeries.
ISSN:1442-6404
1442-9071
DOI:10.1111/ceo.13463