Flow cytometry for near-patient testing in premature neonates reveals variation in platelet function: a novel approach to guide platelet transfusion

Background Neonatal haemorrhaging is often co-observed with thrombocytopenia; however, no evidence of a causal relationship with low platelet count has been reported. Regardless, the administration of a platelet transfusion is often based upon this parameter. Accurate measurement of platelet functio...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Pediatric research 2019-05, Vol.85 (6), p.874-884
Hauptverfasser: Waller, Amie K., Lantos, Lajos, Sammut, Audrienne, Salgin, Burak, McKinney, Harriet, Foster, Holly R., Kriek, Neline, Gibbins, Jonathan M., Stanworth, Simon J., Garner, Stephen F., Venkatesh, Vidheya, Curley, Anna, Belteki, Gusztav, Ghevaert, Cedric
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background Neonatal haemorrhaging is often co-observed with thrombocytopenia; however, no evidence of a causal relationship with low platelet count has been reported. Regardless, the administration of a platelet transfusion is often based upon this parameter. Accurate measurement of platelet function in small volumes of adult blood samples by flow cytometry is well established and we propose that the use of the same technology could provide complementary information to guide the administration of platelet transfusions in premature neonates. Methods In 28 neonates born at 27–41 weeks gestation, platelet function after stimulation agonists was measured using fibrinogen binding and P-selectin expression (a marker of degranulation). Results Platelets of neonates with gestation of ≤36 weeks ( n  = 20) showed reduced fibrinogen binding and degranulation with ADP, and reduced degranulation with CRP-XL. Degranulation Scores of 7837 ± 5548, 22,408 ± 5301 and 53,131 ± 12,102 (mean ± SEM) identified significant differences between three groups: 36 weeks gestation). Fibrinogen binding and degranulation responses to ADP were significantly reduced in suspected septic neonates ( n  = 6) and the Fibrinogen Binding scores clearly separated the septic and healthy group (88.2 ± 10.3 vs 38.6 ± 12.2, P  = 0.03). Conclusions Flow cytometric measurement of platelet function identified clinically different neonatal groups and may eventually contribute to assessment of neonates requiring platelet transfusion.
ISSN:0031-3998
1530-0447
DOI:10.1038/s41390-019-0316-9