Comparison of specimen adequacy and diagnostic accuracy of a 25-gauge and 22-gauge needle in endobronchial ultrasound-guided transbronchial needle aspiration

Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is the preferred diagnostic modality for sampling mediastinal and hilar lymph nodes (LNs). The conventional needle used for sampling is either a 21-gauge (21G) or 22-gauge (22G). A 25-gauge (25G) needle has recently been in...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of thoracic disease 2019-08, Vol.11 (8), p.3643-3649
Hauptverfasser: Di Felice, Christopher, Young, Benjamin, Matta, Maroun
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is the preferred diagnostic modality for sampling mediastinal and hilar lymph nodes (LNs). The conventional needle used for sampling is either a 21-gauge (21G) or 22-gauge (22G). A 25-gauge (25G) needle has recently been introduced with little known regarding its efficacy. A retrospective study was conducted on patients referred for EBUS-TBNA who had LNs sampled using a 25G or 22G needle. A propensity score matching analysis was performed. After matching the groups, each LN was assessed for adequacy and final diagnosis. Non-diagnostic and benign lymphoid specimens were compared with repeat biopsy findings or long-term clinical and radiological follow-up. A total of 158 LNs were included. An adequate sample was obtained in 92.4% (73/79) in the 25G group and 92.4% (73/79) in the 22G group (P=1). The 25G group diagnosed benign lymphoid tissue in 82.3% (65/79), granuloma in 7.6% (6/79) and malignancy in 2.5% (2/79). Six lymph nodes in the 25G group were non-diagnostic (7.6%). The 22G group diagnosed benign lymphoid tissue in 83.5% (66/79), granuloma in 3.8% (3/79) and malignancy in 5.1% (4/79). Six lymph nodes in the 22G group were non-diagnostic (7.6%). The sensitivity, specificity, negative predictive value (NPV) and diagnostic accuracy in the 25G group was 88.9% (95% CI, 51.8-99.7%), 100% (95% CI, 92.1-100%), 97.8% (95% CI, 87.6-99.7%) and 98.2% (95% CI, 90.1-100%), respectively. The sensitivity, specificity, NPV and diagnostic accuracy in the 22G group was 77.8% (95% CI, 40-97.2%), 100% (95% CI, 86.8-100%), 92.9% (95% CI, 79.3-97.8%) and 94.3% (95% CI, 80.8-99.3%), respectively. The 25G and 22G group were comparable in diagnostic accuracy (P=0.7). The 25G and 22G needle achieve comparable specimen adequacy and diagnostic accuracy in EBUS-TBNA.
ISSN:2072-1439
2077-6624
DOI:10.21037/jtd.2019.04.20