Automatic Breast and Fibroglandular Tissue Segmentation in Breast MRI Using Deep Learning by a Fully-Convolutional Residual Neural Network U-Net

Breast segmentation using the U-net architecture was implemented and tested in independent validation datasets to quantify fibroglandular tissue volume in breast MRI. Two datasets were used. The training set was MRI of 286 patients with unilateral breast cancer. The segmentation was done on the cont...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Academic radiology 2019-11, Vol.26 (11), p.1526-1535
Hauptverfasser: Zhang, Yang, Chen, Jeon-Hor, Chang, Kai-Ting, Park, Vivian Youngjean, Kim, Min Jung, Chan, Siwa, Chang, Peter, Chow, Daniel, Luk, Alex, Kwong, Tiffany, Su, Min-Ying
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Breast segmentation using the U-net architecture was implemented and tested in independent validation datasets to quantify fibroglandular tissue volume in breast MRI. Two datasets were used. The training set was MRI of 286 patients with unilateral breast cancer. The segmentation was done on the contralateral normal breasts. The ground truth for the breast and fibroglandular tissue (FGT) was obtained by using a template-based segmentation method. The U-net deep learning algorithm was implemented to analyze the training set, and the final model was obtained using 10-fold cross-validation. The independent validation set was MRI of 28 normal volunteers acquired using four different MR scanners. Dice Similarity Coefficient (DSC), voxel-based accuracy, and Pearson's correlation were used to evaluate the performance. For the 10-fold cross-validation in the initial training set of 286 patients, the DSC range was 0.83–0.98 (mean 0.95 ± 0.02) for breast and 0.73–0.97 (mean 0.91 ± 0.03) for FGT; and the accuracy range was 0.92–0.99 (mean 0.98 ± 0.01) for breast and 0.87–0.99 (mean 0.97 ± 0.01) for FGT. For the entire 224 testing breasts of the 28 normal volunteers in the validation datasets, the mean DSC was 0.86 ± 0.05 for breast, 0.83 ± 0.06 for FGT; and the mean accuracy was 0.94 ± 0.03 for breast and 0.93 ± 0.04 for FGT. The testing results for MRI acquired using four different scanners were comparable. Deep learning based on the U-net algorithm can achieve accurate segmentation results for the breast and FGT on MRI. It may provide a reliable and efficient method to process large number of MR images for quantitative analysis of breast density.
ISSN:1076-6332
1878-4046
DOI:10.1016/j.acra.2019.01.012