Distinguishing Highly Asymmetric Keratoconus Eyes Using Dual Scheimpflug/Placido Analysis

To identify the best metrics or combination of metrics that provide the highest predictive power between normal eyes and the clinically unaffected eye of patients with highly asymmetric keratoconus using data from a Dual Scheimpflug/Placido device. Retrospective case-control study. Combined Dual Sch...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:American journal of ophthalmology 2019-05, Vol.201, p.46-53
Hauptverfasser: Golan, Oren, Piccinini, Andre L., Hwang, Eric S., De Oca Gonzalez, Ildamaris Montes, Krauthammer, Mark, Khandelwal, Sumitra S., Smadja, David, Randleman, J. Bradley
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:To identify the best metrics or combination of metrics that provide the highest predictive power between normal eyes and the clinically unaffected eye of patients with highly asymmetric keratoconus using data from a Dual Scheimpflug/Placido device. Retrospective case-control study. Combined Dual Scheimpflug/Placido imaging was obtained from the Galilei G4 device (Ziemer Ophthalmic Systems AG, Port, Switzerland) in 31 clinically unaffected eyes with highly asymmetric keratoconus and 178 eyes from 178 patients with bilaterally normal corneal examinations that underwent uneventful LASIK with at least 1 year follow-up. Receiver operating characteristic (ROC) curves were generated to determine area under the curve (AUC), sensitivity, and specificity for 87 metrics, and logistic regression modeling was used to determine optimal variable combinations. No individual metric achieved an AUC greater than 0.79. A combined model consisting of 9 metrics yielded an AUC of 0.96, with 90.3% sensitivity and 92.6% specificity. Among those 9 metrics included, 5 related to corneal pachymetry: Opposite Sector Index and Anterior Height BFS Z from the anterior surface, Asphericity and Asymmetry Index, Posterior Height BFS Z, and Posterior Height BFS X from the posterior surface. The strongest variable in the model was the thinnest point location on the horizontal (x) axis. While individual metrics performed poorly, using a combination of metrics from the combined Dual Scheimpflug/Placido device provided a useful model for differentiating normal corneas from the clinically normal eyes of patients with highly asymmetric keratoconus. Pachymetry values were the most impactful metrics. •Dual Scheimpflug/Placido analysis performed well in distinguishing eyes with highly asymmetric keratoconus from normal controls.•No individual variable performed adequately.•A combination of variables, including 5 pachymetry, 2 anterior surface, and 2 posterior surface variables, distinguished the populations with 90.3% sensitivity and 92.6% specificity.
ISSN:0002-9394
1879-1891
DOI:10.1016/j.ajo.2019.01.023