Development of Chronic Sphenoid Sinusitis After Sellar Reconstruction with Medpor Porous Polyethylene Implant

The Medpor porous polyethylene implant is reported to be safe and effective for sellar reconstruction after transsphenoidal surgery (TSS). However, we have observed several cases of delayed chronic sphenoid sinusitis related to the implant. The purpose of this study is to describe the presentation a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:World neurosurgery 2019-03, Vol.123, p.e781-e786
Hauptverfasser: Farrell, Nyssa Fox, Kingdom, Todd T., Getz, Anne E., Lillehei, Kevin O., Youssef, A. Samy, Ramakrishnan, Vijay R.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The Medpor porous polyethylene implant is reported to be safe and effective for sellar reconstruction after transsphenoidal surgery (TSS). However, we have observed several cases of delayed chronic sphenoid sinusitis related to the implant. The purpose of this study is to describe the presentation and management of implant-related sphenoid sinusitis after sellar reconstruction. This is a retrospective study of patients who underwent endonasal TSS with Medpor sellar reconstruction between December 2008 and January 2013 at a tertiary care institution. Patient demographics, initial surgical management, sinonasal symptoms, postoperative imaging, sinusitis management, and resulting outcomes were analyzed. From 2008–2013, 139 patients underwent sellar reconstruction using Medpor. Five patients (3.6%) presented between 8 and 60 months after surgery with chronic sphenoid sinusitis that required surgical management. All 5 patients presented as outpatients for management of headaches and nasal drainage, 4 patients experienced chronic nasal congestion, and 3 patients noted recurrent sinusitis. At the time of revision surgery, all 5 patients were found to have mucosal inflammation and edema surrounding the implant, and 4 of the 5 had an exposed or partially extruded implant that was removed. Reconstruction of the sellar floor may be performed after TSS to prevent postoperative complications. Although porous polyethylene implants have previously been described as safe and effective for this purpose, surgeons should be aware of the risk of subsequent implant extrusion and chronic sphenoid sinusitis that can occur in a delayed manner.
ISSN:1878-8750
1878-8769
DOI:10.1016/j.wneu.2018.12.034