Correlation of histological and microbiological findings in septic and aseptic knee implant failure
Introduction The Musculoskeletal Infection Society (MSIS) has defined specific clinical and laboratory criteria for the diagnosis of periprosthetic joint infection (PJI). In this study we assessed the diagnostic utility of MSIS microbiological and histological criteria for PJI in 138 cases of septic...
Gespeichert in:
Veröffentlicht in: | Archives of orthopaedic and trauma surgery 2019-05, Vol.139 (5), p.717-722 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Introduction
The Musculoskeletal Infection Society (MSIS) has defined specific clinical and laboratory criteria for the diagnosis of periprosthetic joint infection (PJI). In this study we assessed the diagnostic utility of MSIS microbiological and histological criteria for PJI in 138 cases of septic and aseptic knee implant failure.
Materials and methods
Intra-operative samples from 60 cases of knee septic implant failure (SIF) and 78 cases of aseptic implant failure (AIF), defined on the basis of clinical, laboratory and operative findings/surgical management, were analysed microbiologically and histologically. Findings were correlated with the final clinical diagnosis and the specificity, sensitivity, accuracy, positive and negative predictive value of MSIS microbiological and histological criteria for knee PJI were assessed.
Results
80% of SIF cases showed culture of the same organism from two or more samples (ie MSIS microbiological criteria for definite PJI); 8.3% grew an organism from one sample, and 11.7% showed no growth from any sample. 23.1% of AIF cases grew an organism from one sample and 76.9% showed no growth from any sample. MSIS histological criteria for PJI identified 96.7% of SIF cases. The sensitivity, specificity, accuracy and positive and negative predictive value of MSIS histological criteria for PJI were 96.7%, 100%, 98.6%, 100% and 97.5%, respectively. MSIS microbiological and histological criteria identified all AIF cases.
Conclusions
Knee PJI is more often identified by current MSIS histological than microbiological criteria. A significant proportion of SIF cases show either no growth or growth of an organism from only one sample. AIF is identified by both MSIS microbiological and histological criteria. Correlation of clinical, radiological and laboratory findings is required for the diagnosis of knee PJI. |
---|---|
ISSN: | 0936-8051 1434-3916 |
DOI: | 10.1007/s00402-019-03159-x |