"Tailored" endovascular pulmonary valve and root replacement for rupture of a dilated homograft

Current balloon expandable and self-expanding valves have limitations for the treatment of the enlarged right ventricular outflow tract. We report the first use of a tailored Zenith graft in composition with an Edwards Sapien S3 valve as an alternative to high-risk surgery for the treatment of a spo...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Cardiovascular diagnosis and therapy 2018-12, Vol.8 (6), p.820-824
Hauptverfasser: Müller, Götz Christoph, Sinning, Christoph, Zengin-Sahm, Elvin, Stark, Veronika, Mir, Thomas S, Rickers, Carsten, Kozlik-Feldmann, Rainer, Kölbel, Tilo, Schäfer, Ulrich
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Current balloon expandable and self-expanding valves have limitations for the treatment of the enlarged right ventricular outflow tract. We report the first use of a tailored Zenith graft in composition with an Edwards Sapien S3 valve as an alternative to high-risk surgery for the treatment of a spontaneously ruptured homograft in an adult congenital heart disease patient.
ISSN:2223-3652