Comparison between technetium-99m methoxyisobutylisonitrile scintigraphy and ultrasound in the diagnosis of parathyroid adenoma and parathyroid hyperplasia
OBJECTIVEThe aim of this study was to evaluate the value of technetium-99m methoxyisobutylisonitrile (Tc-MIBI) imaging and ultrasound in preoperative localization of parathyroid adenoma (PA) and parathyroid hyperplasia (PH). PARTICIPANTS AND METHODSA retrospective study of Tc-MIBI double-phase scint...
Gespeichert in:
Veröffentlicht in: | Nuclear medicine communications 2018-12, Vol.39 (12), p.1129-1137 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | OBJECTIVEThe aim of this study was to evaluate the value of technetium-99m methoxyisobutylisonitrile (Tc-MIBI) imaging and ultrasound in preoperative localization of parathyroid adenoma (PA) and parathyroid hyperplasia (PH).
PARTICIPANTS AND METHODSA retrospective study of Tc-MIBI double-phase scintigraphy (DPS) was performed in 187 hyperparathyroidism cases with pathologically diagnosed PA or PH. Of these patients, 167 cases underwent ultrasound, and 146 cases underwent Tc-MIBI single-photon emission computed tomography/computed tomography (SPECT/CT). The sensitivity and diagnostic accuracy of ultrasound, Tc-MIBI DPS, and SPECT/CT were compared between PA and PH. Differences in Tc-MIBI DPS, serum parathyroid hormone (PTH), serum calcium and phosphorus, as well as the weight and longest diameter of lesion between PA and PH were also compared.
RESULTSAs per patient-based analysis, the sensitivity of ultrasound, Tc-MIBI DPS, and SPECT/CT was 90.70% (39/43), 95.56% (43/45), and 100.00% (30/30), respectively, for PA, and 93.55% (116/124), 90.85% (129/142), and 93.10% (108/116), respectively, for PH. There were no significant differences in sensitivity of these three imaging methods between PA and PH. However, per lesion-based analysis, the accuracy of ultrasound, Tc-MIBI DPS, and SPECT/CT in detecting PA was 78.43% (40/51), 86.79% (46/53) and 96.88% (31/32), respectively, and the accuracy of Tc-MIBI DPS was higher than that of ultrasound (χ=6.507, P=0.011), and for PH, it was 49.69% (160/322), 40.71% (171/420), and 43.80% (152/347), respectively. The accuracy of ultrasound was higher than that of Tc-MIBI DPS (χ=5.940, P=0.015). The accuracy of a combination of all three examinations of ultrasound+Tc-MIBI DPS, ultrasound+Tc-MIBI SPECT/CT, Tc-MIBI DPS+SPECT/CT, and ultrasound+Tc-MIBI DPS+Tc-MIBI SPECT/CT was 51.51% (154/299), 53.85% (161/299), 50.17% (150/299), and 54.18% (162/299), respectively, which was higher than that of ultrasound (χ=5.273, P=0.022; χ=8.226, P=0.004; χ=3.880, P=0.049; χ=8.702, P=0.003, respectively). Serum levels of PTH and phosphorus were lower in patients with PA than in patients with PH (P |
---|---|
ISSN: | 0143-3636 1473-5628 |
DOI: | 10.1097/MNM.0000000000000921 |