Clinical Study on Complications of Intracranial Ruptured Aneurysm Embolization by Stent-Assisted Coil

BACKGROUND The aim of this study was to retrospectively analyze the incidence of complications of intracranial complex aneurysms embolization by stent-assisted coils, and to investigate the causes of complications and corresponding treatment methods. MATERIAL AND METHODS A total of 71 patients with...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Medical science monitor 2018-11, Vol.24, p.8115-8124
Hauptverfasser: Liu, Yinlong, Wang, Jianren, Lin, Liqing, Sang, Chunsheng, Lin, Zexi, Pan, Yaohua, Fu, Xi'an
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:BACKGROUND The aim of this study was to retrospectively analyze the incidence of complications of intracranial complex aneurysms embolization by stent-assisted coils, and to investigate the causes of complications and corresponding treatment methods. MATERIAL AND METHODS A total of 71 patients with subarachnoid hemorrhage (SAH) underwent stent-assisted coil embolization from 2015 to 2018 were enrolled in this study. Among them, 59 cases were single aneurysm, 12 cases were multiple aneurysms (11 cases with 2 aneurysms and 1 case with 3 aneurysms), for a total of 84 aneurysms. All enrolled patients received stent angioplasty except for 1 case. RESULTS There were 62 aneurysms (73.81%) treated with complete tamponade, 21 aneurysms (25.00%) treated with near-total tamponade and 1 aneurysm (1.19%) treated with partial tamponade. All aneurysms were evaluated based on GOS (Glascow outcome scale): 55 cases had GOS of 5 scores, 12 cases had GOS of 4 scores, 3 cases had GOS of 3 scores, and 1 case had GOS of 1 score. There were 67 SAH patients with good prognosis (GOS of 4-5 scores). In our study, the incidence of complications was 12.7%. Three cases experienced acute thrombosis, 2 cases experienced aneurysm rupture during embolization, and 1 case experienced postoperative focal ischemic changes with mild neurological deficits. CONCLUSIONS Stent-assisted coil embolization is safe, effective, and feasible for the treatment of intracranial ruptured aneurysms. Patients had a favorable outcome of as high as 94.4%. However, clinical skills should be improved to reduce the occurrence of complications. Prompt and timely treatment for complications of intracranial ruptured aneurysm is also of great significance.
ISSN:1643-3750
1234-1010
1643-3750
DOI:10.12659/msm.911773