Clinical decisions support malfunctions in a commercial electronic health record

Summary Objectives : Determine if clinical decision support (CDS) malfunctions occur in a commercial electronic health record (EHR) system, characterize their pathways and describe methods of detection. Methods : We retrospectively examined the firing rate for 226 alert type CDS rules for detection...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied clinical informatics 2017-09, Vol.8 (3), p.910-923
Hauptverfasser: Kassakian, Steven Z., Yackel, Thomas R., Gorman, Paul N., Dorr, David A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Summary Objectives : Determine if clinical decision support (CDS) malfunctions occur in a commercial electronic health record (EHR) system, characterize their pathways and describe methods of detection. Methods : We retrospectively examined the firing rate for 226 alert type CDS rules for detection of anomalies using both expert visualization and statistical process control (SPC) methods over a five year period. Candidate anomalies were investigated and validated. Results : Twenty-one candidate CDS anomalies were identified from 8,300 alert-months. Of these candidate anomalies, four were confirmed as CDS malfunctions, eight as false-positives, and nine could not be classified. The four CDS malfunctions were a result of errors in knowledge management: 1) inadvertent addition and removal of a medication code to the electronic formulary list; 2) a seasonal alert which was not activated; 3) a change in the base data structures; and 4) direct editing of an alert related to its medications. 154 CDS rules (68%) were amenable to SPC methods and the test characteristics were calculated as a sensitivity of 95%, positive predictive value of 29% and F-measure 0.44. Discussion : CDS malfunctions were found to occur in our EHR. All of the pathways for these malfunctions can be described as knowledge management errors. Expert visualization is a robust method of detection, but is resource intensive. SPC-based methods, when applicable, perform reasonably well retrospectively. Conclusion : CDS anomalies were found to occur in a commercial EHR and visual detection along with SPC analysis represents promising methods of malfunction detection. Citation: Kassakian SZ, Yackel TR, Gorman PN, Dorr DA. Clinical decisions support malfunctions in a commercial electronic health record. Appl Clin Inform 2017; 8: 910–923 https://doi.org/10.4338/ACI-2017-01-RA-0006
ISSN:1869-0327
1869-0327
DOI:10.4338/ACI-2017-01-RA-0006