Use of the embedded peritoneal dialysis catheter

Introduction The use of embedded peritoneal dialysis (PD) catheters is purported to offer numerous benefits over standard placement. However, the optimum period of embedment and the effect of prolonged embedment on subsequent catheter function remain unclear. Methods This retrospective observational...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Annals of the Royal College of Surgeons of England 2018-09, Vol.100 (7), p.534-544
Hauptverfasser: Sinha, S, Fok, M, Davenport, A, Banga, N, Lindsey, B, Fernando, B, Forman, C J
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Introduction The use of embedded peritoneal dialysis (PD) catheters is purported to offer numerous benefits over standard placement. However, the optimum period of embedment and the effect of prolonged embedment on subsequent catheter function remain unclear. Methods This retrospective observational study looked at adult patients undergoing embedded PD catheter insertion in a large tertiary referral centre in the UK. Possible predictors for catheter non-function at externalisation were investigated. These included patient factors (age, sex, diabetic status, body mass index, ethnicity, smoking status, previous surgery, estimated glomerular filtration rate), procedural factors (modality of surgery, concurrent surgical procedure), duration of catheter embedment and catheter damage at externalisation. Outcomes examined were proportion of catheters functioning after externalisation, futile placement rate, surgical reintervention rate, infectious complication rate and proportion of externalised catheters lost owing to malfunction. Results Sixty-six catheters were embedded and two-thirds (n=47, 63.6%) were externalised after a median embedment period of 39.4 weeks. Of these, 25 (53.2%) functioned on externalisation. Fourteen (63.6%) of the 22 non-functioning catheters were salvaged. The overall utilisation of PD was 34/47 (72.3%) and the futile placement rate was 12.1%. Over half of the externalised catheters (n=27, 57.4%) were lost directly as a result of catheter related complications, with a median survival time of 39.4 weeks. In adjusted analysis, increasing embedment duration was significantly predictive of catheter non-function at externalisation (adjusted odds ratio: 0.957, 95% confidence interval [CI]: 0.929-0.985, p=0.003) while subsequent catheter loss was highly dependent on catheter function at externalisation (hazard ratio: 0.258, 95% CI: 0.112-0.594, p=0.001). Conclusions Prolonged embedment of PD catheters is associated with a significantly higher likelihood of catheter dysfunction following externalisation, which is in turn associated with subsequent catheter loss. We have discontinued the use of this technique in our unit.
ISSN:0035-8843
1478-7083
DOI:10.1308/rcsann.2018.0088