Factors increasing risk of failure following hip arthroscopy: a case control study
We aimed to identify factors such as pre-arthroscopy and intra-operative variables that were associated with failure of hip arthroscopy as a joint preserving operation. We performed a retrospective analysis of a database containing 344 consecutive hip arthroscopies performed at our institution. Fort...
Gespeichert in:
Veröffentlicht in: | Journal of Hip Preservation Surgery 2018-08, Vol.5 (3), p.240-246 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We aimed to identify factors such as pre-arthroscopy and intra-operative variables that were associated with failure of hip arthroscopy as a joint preserving operation. We performed a retrospective analysis of a database containing 344 consecutive hip arthroscopies performed at our institution. Forty-four hips were identified that underwent a subsequent arthroplasty procedure following their hip arthroscopy (cases). Sixty-six control hips (hip arthroscopy with no subsequent arthroplasty) were randomly selected from the same database. Cases and controls were matched for age, sex and follow-up (
= 0.59, 0.48, 0.10, respectively). Pre-operative radiographs/MRI scans plus intra-operative findings were analysed to identify factors associated with failure. Both a lower centre edge angle and higher acetabular index on pre-operative radiographs were associated with higher rates of failure (
|
---|---|
ISSN: | 2054-8397 2054-8397 |