Variation in the Dispersions of Powder Liquid Ratios in Hand-Mix Glass Ionomers
The Powder/Liquid Ratio (PLR) influence, and the literature regarding the handling and physical properties of Glass Ionomer restorative materials (GIC) were investigated. The objective of the study was to compare the PLR variability and magnitude in hand-mix GICs, as dispensed for clinical use. From...
Gespeichert in:
Veröffentlicht in: | The open dentistry journal 2018-01, Vol.12 (1), p.647-654 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The Powder/Liquid Ratio (PLR) influence, and the literature regarding the handling and physical properties of Glass Ionomer restorative materials (GIC) were investigated.
The objective of the study was to compare the PLR variability and magnitude in hand-mix GICs, as dispensed for clinical use. From the recorded individual powder and liquid weights, additional comparisons could be made by pairing the various "extreme" outer observations in relation to the manufacturer's PLR.
The materials assessed were Ketac Universal Hand-mix (KUH), Riva Self Cure Hand-mix (RSCH) and Fuji IX GP Hand-mix (FIXH). Twenty scoops of powder were paired with twenty drops of liquid, as would be the case in the clinical scenario. Statistical analysis was completed with the Kruskal Wallis H test, Intraclass Correlation (ICC) and straight line regressions with One-way ANOVA and the post-hoc Tukey HSD Test ( |
---|---|
ISSN: | 1874-2106 1874-2106 |
DOI: | 10.2174/1745017901814010647 |