Misdiagnosis of abdominal aortic dissection: image findings with the Nellix endovascular aneurysm sealing system

The Nellix endovascular aneurysm sealing system is a relatively new aortic endoprosthesis designed to overcome the problems associated with traditional methods of endovascular aneurysm repair. We report a case in which a 65-year-old male with abdominal pain was mistakenly diagnosed with an acute aor...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:BJR case reports 2016-01, Vol.2 (2), p.20150318
Hauptverfasser: de Souza, Peter James, Rodway, Alexander, Pankhania, Ajay
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The Nellix endovascular aneurysm sealing system is a relatively new aortic endoprosthesis designed to overcome the problems associated with traditional methods of endovascular aneurysm repair. We report a case in which a 65-year-old male with abdominal pain was mistakenly diagnosed with an acute aortic dissection 7 days postoperatively after Nellix stent insertion, on the basis of the CT angiography findings. This report highlights the typical radiological appearances of the Nellix stent.
ISSN:2055-7159
2055-7159
DOI:10.1259/bjrcr.20150318