An Unusual Method for Controlling Bile Leak from an Immature T-tube Fistula

T-tubes have been used by surgeons for the decompression of the choledocus for over a hundred years. Errors in the operative technique and patient-related risk factors, such as immune comprehensive therapy, diabetes mellitus, steroid drug usage, T-tube morphology, T-tube material, and the T-tube ext...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Curēus (Palo Alto, CA) CA), 2018-05, Vol.10 (5), p.e2560
Hauptverfasser: Ferhatoglu, Murat F, Uyanik, Sadik A, Filiz, Ali I
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:T-tubes have been used by surgeons for the decompression of the choledocus for over a hundred years. Errors in the operative technique and patient-related risk factors, such as immune comprehensive therapy, diabetes mellitus, steroid drug usage, T-tube morphology, T-tube material, and the T-tube extraction technique, are some of the factors that affect the risk of bile leak. In most cases, a surgical approach is required. Herein, we present a case of bile leak after T-tube removal and an unusual solution to this difficult complication.
ISSN:2168-8184
2168-8184