Development, validation and utilization of a highly sensitive LC-MS/MS method for quantification of levonorgestrel released from a subdermal implant in human plasma

Levonorgestrel (LNG) is a synthetic progestin that is available in oral contraceptive tablets, a subdermal implant, and an intrauterine system for contraception. LNG pharmacokinetics are a pivotal determinant of contraceptive efficacy and essential in assessing drug-drug interactions influencing LNG...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of chromatography. B, Analytical technologies in the biomedical and life sciences Analytical technologies in the biomedical and life sciences, 2018-05, Vol.1084, p.106-112
Hauptverfasser: Cirrincione, Lauren R., Penchala, Sujan Dilly, Scarsi, Kimberly K., Podany, Anthony T., Winchester, Lee C., Back, David J., Khoo, Saye H., Fletcher, Courtney V., Siccardi, Marco, Else, Laura J.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Levonorgestrel (LNG) is a synthetic progestin that is available in oral contraceptive tablets, a subdermal implant, and an intrauterine system for contraception. LNG pharmacokinetics are a pivotal determinant of contraceptive efficacy and essential in assessing drug-drug interactions influencing LNG exposure following different routes of LNG administration. A highly sensitive LC-MS/MS method was developed and validated to quantify levonorgestrel in human plasma. Liquid-liquid extraction was utilized with a sample volume of 500 μL to extract levonorgestrel from plasma. Chromatographic separation of LNG was achieved with a Fortis™ C18 (3 μm: 100 mm × 2.1 mm) reverse phase analytical column. The mobile phases consisted of de-ionized water plus 0.1% NH4OH (100:0.1%, v/v) (A), and methanol plus 0.1% NH4OH (100:0.1%, v/v) (B) delivered as a gradient at a flow rate of 400 μL/min. Detection of LNG and internal standard (D-(−)-norgestrel-d7) was achieved using positive polarity mode monitoring at 313.2–245.2 amu and 320.1–251.2 amu, respectively. The assay was linear over the calibration range of 49.6 to 1500 pg/mL. This method was used to quantify plasma LNG released by subdermal implant in support of a drug interaction study among women with HIV receiving efavirenz- or nevirapine-based antiretroviral therapy. •Development of sensitive LC-MS/MS method for quantification of LNG in human plasma•Application of method for determination of LNG released by subdermal implant•Method used in pharmacokinetic study in women living with HIV receiving ART
ISSN:1570-0232
1873-376X
DOI:10.1016/j.jchromb.2018.03.023