Influence of enhancement filters in apical bone loss measurement: A cone-beam computed tomography study

The use of cone-beam computed tomography images (CBCT) providing a better assessment of bone injuries, although the sensibility of lesions measurement might be improved by the use of enhancement filters. Objective: This study aimed to analyze the influence of enhancement filters in apical bone loss...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of clinical and experimental dentistry 2017-04, Vol.9 (4), p.e516-e519
Hauptverfasser: de Sousa, Emerson-Tavares, Pinheiro, Mayara-Abreu, Maciel, Patrícia-Pereira, Sales, Marcelo-Augusto-Oliveira
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The use of cone-beam computed tomography images (CBCT) providing a better assessment of bone injuries, although the sensibility of lesions measurement might be improved by the use of enhancement filters. Objective: This study aimed to analyze the influence of enhancement filters in apical bone loss measurement. Eighteen CBCT cases randomly selected of apical bone loss were evaluated. The analyses were carried out following the evaluation in axial, coronal and sagittal protocols, using enhancement filters as Hard, Normal, and Very Sharp. The variables were statistically analyzed by Friedman and Wilcoxon test, Spearman's rho, and intraclass correlation coefficient. The differences between filters in axial and sagittal protocols were significant (
ISSN:1989-5488
1989-5488
DOI:10.4317/jced.53496