Blood flow characteristics in the ascending aorta after aortic valve replacement—a pilot study using 4D-flow MRI

Abstract Background Aortic remodeling after aortic valve replacement (AVR) might be influenced by the postoperative blood flow pattern in the ascending aorta. This pilot study used flow-sensitive four-dimensional magnetic resonance imaging (4D-flow) to describe ascending aortic flow characteristics...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International journal of cardiology 2014-01, Vol.170 (3), p.426-433
Hauptverfasser: von Knobelsdorff-Brenkenhoff, Florian, Trauzeddel, Ralf F, Barker, Alex J, Gruettner, Henriette, Markl, Michael, Schulz-Menger, Jeanette
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Background Aortic remodeling after aortic valve replacement (AVR) might be influenced by the postoperative blood flow pattern in the ascending aorta. This pilot study used flow-sensitive four-dimensional magnetic resonance imaging (4D-flow) to describe ascending aortic flow characteristics after various types of AVR. Methods 4D-flow was acquired in 38 AVR patients ( n = 9 mechanical, n = 8 stentless bioprosthesis, n = 14 stented bioprosthesis, n = 7 autograft) and 9 healthy controls. Analysis included grading of vortex and helix flow (0–3 point scale), assessment of systolic flow eccentricity (1–3 point scale), and quantification of the segmental distribution of peak systolic wall shear stress (WSSpeak ) in the ascending aorta. Results Compared to controls, mechanical prostheses showed the most distinct vorticity (2.7 ± 0.5 vs. 0.7 ± 0.7; p < 0.001), while stented bioprostheses exhibited most distinct helicity (2.6 ± 0.7 vs. 1.6 ± 0.5; p = 0.002). Instead of a physiologic central flow, all stented, stentless and mechanical prostheses showed eccentric flow jets mainly directed towards the right-anterior aortic wall. Stented and stentless prostheses showed an asymmetric distribution of WSSpeak along the aortic circumference, with significantly increased local WSSpeak where the flow jet impinged on the aortic wall. Local WSSpeak was higher in stented (1.4 ± 0.7 N/m2 ) and stentless (1.3 ± 0.7 N/m2 ) compared to autografts (0.6 ± 0.2 N/m2 ; p = 0.005 and p = 0.008) and controls (0.7 ± 0.1 N/m2 ; p = 0.017 and p = 0.027). Autografts exhibited lower absolute WSSpeak than controls (0.4 ± 0.1 N/m2 vs. 0.7 ± 0.2 N/m2 ; p = 0.003). Conclusions Flow characteristics in the ascending aorta after AVR are different from native aortic valves and differ between various types of AVR.
ISSN:0167-5273
1874-1754
DOI:10.1016/j.ijcard.2013.11.034