Laminar screw fixation in the subaxial cervical spine: A report on three cases

Although laminar screw fixation is often used at the C2 and C7 levels, only few previous case reports have presented the use of laminar screws at the C3-C6 levels. Here, we report a novel fixation method involving the use of practical laminar screws in the subaxial spine. We used laminar screws in t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:World journal of orthopedics 2016-10, Vol.7 (10), p.695-699
Hauptverfasser: Tanabe, Hironori, Aota, Yoichi, Saito, Tomoyuki
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Although laminar screw fixation is often used at the C2 and C7 levels, only few previous case reports have presented the use of laminar screws at the C3-C6 levels. Here, we report a novel fixation method involving the use of practical laminar screws in the subaxial spine. We used laminar screws in the subaxial cervical spine in two cases to prevent vertebral artery injury and in one case to minimize exposure of the lamina. This laminar screw technique was successful in all three cases with adequate spinal rigidity, which was achieved without complications. The use of laminar screws in the subaxial cervical spine is a useful option for posterior fusion of the cervical spine.
ISSN:2218-5836
2218-5836
DOI:10.5312/wjo.v7.i10.695